To: Jim Stone <1789alpine@gmail.com> 2903e8d5c8f:6.0.391,18.0.790,17.0.607.475.0000000 definitions=2021-08-21_08:2021-08-20_02,2021-08-21_08,2020-04-07_01 signatures=0 spamscore=0 mlxlogscore=999 phishscore=0 bulkscore=0 suspectscore=0 clxscore=1015 malwarescore=0 adultscore=0 classifier=spam adjust=0 reason=mlx scancount=1 engine=8.12.0-2009150000 definitions=main-2108210123
Subject: Re: [Shop-talk] LP Generator supply
From: Pat Horne <patintexas@icloud.com>
Date: Sat, 21 Aug 2021 14:46:51 -0500
Cc: Shop Talk <shop-talk@autox.team.net>
Delivered-to: mharc@autox.team.net
Delivered-to: shop-talk@autox.team.net
References: <027899F9-876C-4CD0-8A43-33F46A324516@gmail.com>
--===============5139344982350372128==
Content-Transfer-Encoding: 7bit


--Apple-Mail-F948A1DC-F61B-4F1D-AA19-D8A1A6DB69CC
        charset=utf-8
Content-Transfer-Encoding: quoted-printable

Silly question. Did you talk to the folks that installed the generator?

Peace,
Pat

Pat Horne=20
We support Habitat for Humanity


On Aug 21, 2021, at 1:08 PM, Jim Stone <1789alpine@gmail.com> wrote:

=EF=BB=BFI am on Eastern Long Island, directly in one of the projected paths=
 of Hurricane Henri.  We are being told to plan for 7-10 days without power,=
 although FWIW we were only powerless for 4 days following Sandy.  Shortly a=
fter Sandy I purchased an LP Generator (https://www.jbtools.com/buffalo-tool=
s-gen4000lp-4000-watt-propane-generator/?wi=3Doff&gclid=3DCjwKCAjwyIKJBhBPEi=
wAu7zll1U54VH4euJneVO0jmOzjdgwy6-t0MUdEtaEHYXf_7W0sQxKo54TphoC__4QAvD_BwE) w=
hich, of course, I have never needed, although I do run it periodically to b=
e safe.  It is designed to run off of LP tanks and comes with a standard reg=
ulator.  A little Googling shows the following specs for the regulator:

Low Pressure Regulator
Inlet Pressure:               25-250PSIG
Outlet Pressure:            280mmH2O=3D (11"W.C.)
Flow Capacity(MAX):    119000(BTU/hr)

We use Propane for DHW and heat and have a 500 gallon in-ground tank.   I ha=
d an outside gas line stubbed out when the house was remodeled, just in case=
 I ever needed it and I would like to be able to connect the generator direc=
tly to the house supply and avoid having to depend on the portable tanks.  T=
he house supply is regulated and, as an example, here are the specs for the w=
ater heater:

Max Inlet Gas Pressure:    13.0 =E2=80=9CW.C.
Min Inlet Gas Pressure:     8.0 =E2=80=9CW.C.
Recovery Rating:               206/Gallons/HR
Max Working Pressure:     150psi
Max Output:                       180,000 BTU/HR
Max Input:                          11,000 BTU/HR
Manifold Pressure:             3.9 =E2=80=9CW.C. (For Max Input)

Am I missing anything, or should I be able to hook the generator directly to=
 the house supply without the regulator?  For the record, I tried it once wi=
th the regulator attached and it barely ran and didn=E2=80=99t put out any a=
ppreciable power.  I always meant to research this before I needed it, but l=
ike many of us, never got around to it until now.

Thanks,
Jim


_______________________________________________

Shop-talk@autox.team.net
Archive: http://www.team.net/pipermail/shop-talk http://autox.team.net/archi=
ve

as@icloud.com


--Apple-Mail-F948A1DC-F61B-4F1D-AA19-D8A1A6DB69CC
        charset=utf-8
Content-Transfer-Encoding: quoted-printable

<html><head><meta http-equiv=3D"content-type" content=3D"text/html; charset=3D=
utf-8"></head><body dir=3D"auto">Silly question. Did you talk to the folks t=
hat installed the generator?<div><br></div><div>Peace,</div><div>Pat<br><br>=
<div dir=3D"ltr">Pat Horne&nbsp;<div>We support Habitat for Humanity</div><d=
iv><br></div></div><div dir=3D"ltr"><br>On Aug 21, 2021, at 1:08 PM, Jim Sto=
ne &lt;1789alpine@gmail.com&gt; wrote:<br><br></div><div dir=3D"ltr">=EF=BB=BF=
<meta http-equiv=3D"Content-Type" content=3D"text/html; charset=3Dutf-8">I a=
m on Eastern Long Island, directly in one of the projected paths of Hurrican=
e Henri. &nbsp;We are being told to plan for 7-10 days without power, althou=
gh FWIW we were only powerless for 4 days following Sandy. &nbsp;Shortly aft=
er Sandy I purchased an LP Generator (<a href=3D"https://www.jbtools.com/buf=
falo-tools-gen4000lp-4000-watt-propane-generator/?wi=3Doff&amp;gclid=3DCjwKC=
AjwyIKJBhBPEiwAu7zll1U54VH4euJneVO0jmOzjdgwy6-t0MUdEtaEHYXf_7W0sQxKo54TphoC_=
_4QAvD_BwE" class=3D"">https://www.jbtools.com/buffalo-tools-gen4000lp-4000-=
watt-propane-generator/?wi=3Doff&amp;gclid=3DCjwKCAjwyIKJBhBPEiwAu7zll1U54VH=
4euJneVO0jmOzjdgwy6-t0MUdEtaEHYXf_7W0sQxKo54TphoC__4QAvD_BwE</a>) which, of c=
ourse, I have never needed, although I do run it periodically to be safe. &n=
bsp;It is designed to run off of LP tanks and comes with a standard regulato=
r. &nbsp;A little Googling shows the following specs for the regulator:<div c=
lass=3D""><br class=3D""></div><div class=3D""><ul class=3D"MailOutline"><li=
 class=3D"">Low Pressure Regulator</li><li class=3D"">Inlet Pressure: &nbsp;=
 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 25-250PSIG</li><li class=3D"">Out=
let Pressure: &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;280mmH2O=3D (11"W.C.)=
</li><li class=3D"">Flow Capacity(MAX): &nbsp; &nbsp;119000(BTU/hr)</li></ul=
><div class=3D""><br class=3D""></div></div><div class=3D"">We use Propane f=
or DHW and heat and have a 500 gallon in-ground tank. &nbsp; I had an outsid=
e gas line stubbed out when the house was remodeled, just in case I ever nee=
ded it and I would like to be able to connect the generator directly to the h=
ouse supply and avoid having to depend on the portable tanks. &nbsp;The hous=
e supply is regulated and, as an example, here are the specs for the water h=
eater:</div><div class=3D""><br class=3D""></div><div class=3D""><ul class=3D=
"MailOutline"><li class=3D"">Max Inlet Gas Pressure: &nbsp; &nbsp;13.0 =E2=80=
=9CW.C.</li><li class=3D"">Min Inlet Gas Pressure: &nbsp; &nbsp; 8.0 =E2=80=9C=
W.C.</li><li class=3D"">Recovery Rating: &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &=
nbsp; &nbsp; 206/Gallons/HR</li><li class=3D"">Max Working Pressure: &nbsp; &=
nbsp; 150psi</li><li class=3D"">Max Output: &nbsp; &nbsp; &nbsp; &nbsp; &nbs=
p; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 180,000 BTU/HR</li><li class=3D=
"">Max Input: &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;=
 &nbsp; &nbsp; &nbsp; &nbsp;11,000 BTU/HR</li><li class=3D"">Manifold Pressu=
re: &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 3.9 =E2=80=9CW.C. (For Max Inp=
ut)</li></ul><div class=3D""><br class=3D""></div><div class=3D"">Am I missi=
ng anything, or should I be able to hook the generator directly to the house=
 supply without the regulator? &nbsp;For the record, I tried it once with th=
e regulator attached and it barely ran and didn=E2=80=99t put out any apprec=
iable power. &nbsp;I always meant to research this before I needed it, but l=
ike many of us, never got around to it until now.</div><div class=3D""><br c=
lass=3D""></div><div class=3D"">Thanks,</div><div class=3D"">Jim</div><div c=
lass=3D""><br class=3D""></div></div><div class=3D""><br class=3D""></div><s=
pan>_______________________________________________</span><br><span></span><=
br><span>Shop-talk@autox.team.net</span><br><span>Donate: http://www.team.ne=
t/donate.html</span><br><span>Suggested annual donation &nbsp;$12.96</span><=
br><span>Archive: http://www.team.net/pipermail/shop-talk http://autox.team.=
net/archive</span><br><span></span><br><span>Unsubscribe/Manage: http://auto=
x.team.net/mailman/options/shop-talk/patintexas@icloud.com</span><br><span><=
/span><br></div></div></body></html>=

--Apple-Mail-F948A1DC-F61B-4F1D-AA19-D8A1A6DB69CC--

--===============5139344982350372128==
Content-Transfer-Encoding: 7bit
Content-Disposition: inline

_______________________________________________

Shop-talk@autox.team.net
Archive: http://www.team.net/pipermail/shop-talk http://autox.team.net/archive



--===============5139344982350372128==--

<Prev in Thread] Current Thread [Next in Thread>