> On the TR4A wiring diagram the dotted line wire between #28 (Voltage Stab)
> and 29 (Heater Blower Motor, optional) is not marked with a colour(s).
>
> I suspect this is green and black. Can anyone confirm?
Are you talking about the line between the VS and the heater fan switch? Or
the wire from the switch to the motor?
I believe the wire from the VS to the switch should be solid green. Green
with a tracer would make sense for the line from the switch to the motor;
but I believe the tracer is usually slate.
Green/black is the line from the fuel gauge to the sender.
-- Randall
_______________________________________________
Support Team.Net http://www.team.net/donate.html
This list supported in part by the Vintage Triumph Register
http://www.vtr.org
Triumphs@autox.team.net
http://autox.team.net/mailman/listinfo/triumphs
http://www.team.net/archive
|