healeys
[Top] [All Lists]

[Healeys] Dual fuel pumps

Subject: [Healeys] Dual fuel pumps
From: coudesluijs at chello.nl (Oudesluys)
Date: Sat, 16 Apr 2011 09:28:32 +0200
References: <BANLkTimmQGqXcwPtcxSt3u8DXkyqt7K-uA@mail.gmail.com>
Keith,
I do understand why you want to put them in series but if you 
accidentally switch them on both you have double the fuel pressure. 
Better fit them parallel with an electrically operated valve (4) before 
and after each switch. The valves are operated by the same feed wire as 
the corresponding pump. These valves are easily sourced from LPG fitters.
This way there is no circulation through the faulty pump and you will 
have no leakage if something horrible has happened to a pump.
Kees Oudesluijs

[demime 1.01d removed an attachment of type text/x-vcard which had a name of 
coudesluijs.vcf]

<Prev in Thread] Current Thread [Next in Thread>