 From the instructions from the kit:

"The shield is set by connecting the pump to a voltage supply of between 
6 & 12V.  Positive earth pumps must be connected withe the Positive wire 
to the pumps body terminal.  Negative ... (DNA) ... Place the shield 
adjustment tube <just a short plastic tube> over the shield finger and 
hold the pump securely, briefly touch the terminal bolt on the circuit 
board with the other battery lead.  At the same time move the shield in 
towards the magnet.  The pump should begin to make a faint audible 
click, as the magnet rises and turns on the hall switch (which turns on 
the solenoid) then drops back.

If the magnet rises to full lift and stays there, either the shield has 
been moved too far in or the solenoid internal connections are connected 
in reverse."


FWIW, I believe these pumps are tested at the factory after assembly.  I 
gotta believe it's not the pump, but don't know what else it could be.


bs


Ron Davies wrote:
> OK, I disconnected the gas fittings from the SU pump and it still won't
> click so I assume the filter is OK?
> That leaves the pump. Someone thought there might be an adjustment.
> There were no directions in the box.
> Anyone know what the adjustment might be or what I could try next before
> returning the pump?
> TIA
> Ron
> 67 BJ8