My tank displaces approx. .37cuft.. At .24cfm, it should take ~1.6min. to
fill from empty. Is continuos duty necessary or worth the extra cost, even
with some leakage?
GM
----- Original Message -----
> As far as which compressor to use, I have always used the Thomas
> 405ADC38/12. It is rated at 100# max. but I had a regulator set at 115#
and
> it never had a problem getting to that pressure. It is a continuous
pressure
> compressor(it can run for long periods) where the other suggested units
> (215ADC38/12 and 315CDC56/12) are intermittent duty compressors. They can
> run for 5 minutes and then must be off for 20. Granted, if you have a no
> leak system the intermittent units should be OK but I have had nothing but
> good luck with the 405 unit.
> George.
>
>
> George J. Malaska, VIN#768,#1548.
|