Were any of those failures digital or were they all analog?
From: Triumphs <triumphs-bounces@autox.team.net> On Behalf Of andrew
uprichard
Sent: Saturday, June 27, 2020 7:31 AM
To: 'Bill Brewer' <billbrewer59@yahoo.com>; 'Triumphs List'
<triumphs@autox.team.net>
Subject: Re: [TR] Perplexing A-Type OD Problem
Sorry - Randall is in Kindred hospital, Paramount, CA
From: andrew uprichard <auprichard@uprichard.net
Sent: Saturday, June 27, 2020 8:06 AM
Subject: RE: [TR] Perplexing A-Type OD Problem
I recently went through FOUR aftermarket voltage regulators on a TR4. They
came from different vendors and lasted anywhere from a few minutes to a few
weeks. I sourced an original from Marv Gruber and it has worked fine ever
since. What are the chances you could get your hands on a nice original
solenoid?
Randall Young is in a rehab hospital (Kindred hospital in Pasadena)
following a stroke. I have spoken to him several times and encouraged him
to comply with the physical therapy as there were so many TRs waiting for
his advice! It has been a bad year for him - his father died just a few
months ago.
Andrew Uprichard
Jackson, michigan
From: Triumphs <triumphs-bounces@autox.team.net
Sent: Friday, June 26, 2020 10:00 PM
>
Subject: [TR] Perplexing A-Type OD Problem
Hi Listers,
I was on a trip driving my TR3 that has a TR4 overdrive trans in it.
The OD had been working fine and then suddenly nothing would happen when I
threw the switch. I checked the relay with a test lamp and the C2 output
terminal (yellow/purple wire) lights up fine but the solenoid wouldn't
actuate. I tested the solenoid (Moss - aftermarket) on my workbench and it
seems to pull in fine. It probably only has 5,000 miles on it and looks
almost new. I put it back in the car and it doesn't actuate. I ran a new
wire straight from the C2 terminal on the relay to the installed solenoid
and it still doesn't actuate, although I can move the actuation lever by
hand. Evidently the solenoid is bad again. It seems like I go through OD
solenoids fairly regularly. Randall (does anyone know how he is doing???)
had me install a small "bounceback resistor" on the from the C2 output
terminal on the relay to ground to eliminate bounceback voltage spikes. Any
idea why I would be going through solenoids so regularly? I seem to change
them out about every 10,000 miles.
Could it be a grounding issue for the solenoid? It seems like there
would be plenty of electrical continuity from the transmission to the engine
and chassis, so that shouldn't be it.
Thanks in advance,
-Bill Brewer
------=_NextPart_000_0027_01D64C5C.3C486D10
charset="us-ascii"
Content-Transfer-Encoding: quoted-printable
<html xmlns:v=3D"urn:schemas-microsoft-com:vml" =
xmlns:o=3D"urn:schemas-microsoft-com:office:office" =
xmlns:w=3D"urn:schemas-microsoft-com:office:word" =
xmlns:m=3D"http://schemas.microsoft.com/office/2004/12/omml" =
xmlns=3D"http://www.w3.org/TR/REC-html40"><head><META =
HTTP-EQUIV=3D"Content-Type" CONTENT=3D"text/html; =
charset=3Dus-ascii"><meta name=3DGenerator content=3D"Microsoft Word 15 =
(filtered medium)"><style><!--
/* Font Definitions */
@font-face
{font-family:"Cambria Math";
panose-1:2 4 5 3 5 4 6 3 2 4;}
@font-face
{font-family:Calibri;
panose-1:2 15 5 2 2 2 4 3 2 4;}
/* Style Definitions */
p.MsoNormal, li.MsoNormal, div.MsoNormal
{margin:0in;
margin-bottom:.0001pt;
font-size:11.0pt;
font-family:"Calibri",sans-serif;}
a:link, span.MsoHyperlink
{mso-style-priority:99;
color:blue;
text-decoration:underline;}
span.EmailStyle20
{mso-style-type:personal-reply;
font-family:"Calibri",sans-serif;
color:windowtext;}
.MsoChpDefault
{mso-style-type:export-only;
font-size:10.0pt;}
@page WordSection1
{size:8.5in 11.0in;
margin:1.0in 1.0in 1.0in 1.0in;}
div.WordSection1
{page:WordSection1;}
--></style><!--[if gte mso 9]><xml>
<o:shapedefaults v:ext=3D"edit" spidmax=3D"1026" />
</xml><![endif]--><!--[if gte mso 9]><xml>
<o:shapelayout v:ext=3D"edit">
<o:idmap v:ext=3D"edit" data=3D"1" />
</o:shapelayout></xml><![endif]--></head><body lang=3DEN-US link=3Dblue =
vlink=3Dpurple><div class=3DWordSection1><p class=3DMsoNormal>Were any =
of those failures digital or were they all analog?<o:p></o:p></p><p =
class=3DMsoNormal><o:p> </o:p></p><div><div =
style=3D'border:none;border-top:solid #E1E1E1 1.0pt;padding:3.0pt 0in =
0in 0in'><p class=3DMsoNormal><b>From:</b> Triumphs =
<triumphs-bounces@autox.team.net> <b>On Behalf Of </b>andrew =
uprichard<br><b>Sent:</b> Saturday, June 27, 2020 7:31 AM<br><b>To:</b> =
'Bill Brewer' <billbrewer59@yahoo.com>; 'Triumphs List' =
<triumphs@autox.team.net><br><b>Subject:</b> Re: [TR] Perplexing =
A-Type OD Problem<o:p></o:p></p></div></div><p =
class=3DMsoNormal><o:p> </o:p></p><p class=3DMsoNormal><span =
style=3D'font-family:"Times New Roman",serif;color:#1F497D'>Sorry =
– Randall is in Kindred hospital, <u>Paramount</u>, =
CA<o:p></o:p></span></p><p class=3DMsoNormal><span =
style=3D'font-family:"Times New =
Roman",serif;color:#1F497D'><o:p> </o:p></span></p><div><div =
style=3D'border:none;border-top:solid #E1E1E1 1.0pt;padding:3.0pt 0in =
0in 0in'><p class=3DMsoNormal><b>From:</b> andrew uprichard <<a =
href=3D"mailto:auprichard@uprichard.net">auprichard@uprichard.net</a>>=
<br><b>Sent:</b> Saturday, June 27, 2020 8:06 AM<br><b>To:</b> 'Bill =
Brewer' <<a =
href=3D"mailto:billbrewer59@yahoo.com">billbrewer59@yahoo.com</a>>; =
'Triumphs List' <<a =
href=3D"mailto:triumphs@autox.team.net">triumphs@autox.team.net</a>><b=
r><b>Subject:</b> RE: [TR] Perplexing A-Type OD =
Problem<o:p></o:p></p></div></div><p =
class=3DMsoNormal><o:p> </o:p></p><p class=3DMsoNormal><span =
style=3D'font-family:"Times New Roman",serif;color:#1F497D'>I recently =
went through FOUR aftermarket voltage regulators on a TR4. They =
came from different vendors and lasted anywhere from a few minutes to a =
few weeks. I sourced an original from Marv Gruber and it has =
worked fine ever since. What are the chances you could get your =
hands on a nice original solenoid?<o:p></o:p></span></p><p =
class=3DMsoNormal><span style=3D'font-family:"Times New =
Roman",serif;color:#1F497D'><o:p> </o:p></span></p><p =
class=3DMsoNormal><span style=3D'font-family:"Times New =
Roman",serif;color:#1F497D'>Randall Young is in a rehab hospital =
(Kindred hospital in Pasadena) following a stroke. I have spoken =
to him several times and encouraged him to comply with the physical =
therapy as there were so many TRs waiting for his advice! It has =
been a bad year for him – his father died just a few months =
ago.<o:p></o:p></span></p><p class=3DMsoNormal><span =
style=3D'font-family:"Times New =
Roman",serif;color:#1F497D'><o:p> </o:p></span></p><p =
class=3DMsoNormal><span style=3D'font-family:"Times New =
Roman",serif;color:#1F497D'>Andrew Uprichard<o:p></o:p></span></p><p =
class=3DMsoNormal><span style=3D'font-family:"Times New =
Roman",serif;color:#1F497D'>Jackson, michigan<o:p></o:p></span></p><p =
class=3DMsoNormal><span style=3D'font-family:"Times New =
Roman",serif;color:#1F497D'><o:p> </o:p></span></p><div><div =
style=3D'border:none;border-top:solid #E1E1E1 1.0pt;padding:3.0pt 0in =
0in 0in'><p class=3DMsoNormal><b>From:</b> Triumphs <<a =
href=3D"mailto:triumphs-bounces@autox.team.net">triumphs-bounces@autox.te=
am.net</a>> <b>On Behalf Of </b>Bill Brewer<br><b>Sent:</b> Friday, =
June 26, 2020 10:00 PM<br><b>To:</b> Triumphs List <<a =
href=3D"mailto:triumphs@autox.team.net">triumphs@autox.team.net</a>><b=
r><b>Subject:</b> [TR] Perplexing A-Type OD =
Problem<o:p></o:p></p></div></div><p =
class=3DMsoNormal><o:p> </o:p></p><p class=3DMsoNormal>Hi =
Listers,<o:p></o:p></p><p class=3DMsoNormal> I =
was on a trip driving my TR3 that has a TR4 overdrive trans in it. The =
OD had been working fine and then suddenly nothing would happen when I =
threw the switch. I checked the relay with a test lamp and the C2 output =
terminal (yellow/purple wire) lights up fine but the solenoid =
wouldn’t actuate. I tested the solenoid (Moss – aftermarket) =
on my workbench and it seems to pull in fine. It probably only has 5,000 =
miles on it and looks almost new. I put it back in the car and it =
doesn’t actuate. I ran a new wire straight from the C2 terminal on =
the relay to the installed solenoid and it still doesn’t actuate, =
although I can move the actuation lever by hand. Evidently the solenoid =
is bad again. It seems like I go through OD solenoids fairly regularly. =
Randall (does anyone know how he is doing???) had me install a small =
“bounceback resistor” on the from the C2 output terminal on =
the relay to ground to eliminate bounceback voltage spikes. Any idea why =
I would be going through solenoids so regularly? I seem to change them =
out about every 10,000 miles.<o:p></o:p></p><p =
class=3DMsoNormal> Could it be a grounding issue =
for the solenoid? It seems like there would be plenty of electrical =
continuity from the transmission to the engine and chassis, so that =
shouldn’t be it.<o:p></o:p></p><p =
class=3DMsoNormal> Thanks in =
advance,<o:p></o:p></p><p class=3DMsoNormal><o:p> </o:p></p><p =
class=3DMsoNormal> -Bill =
Brewer<o:p></o:p></p></div></body></html>
------=_NextPart_000_0027_01D64C5C.3C486D10--
--===============2671949188793669747==
Content-Transfer-Encoding: 7bit
Content-Disposition: inline
** triumphs@autox.team.net **
Archive: http://www.team.net/pipermail/triumphs http://www.team.net/archive
--===============2671949188793669747==--
|