Tim Buja wrote : <snip> > The UL 248-14 standard ... The fuse must open at > 135% of rated current within one hour. <snip> > British Standard BS 4265 (now IEC 60127) calls for 150% of rated current for > 1 hour minimum In other words, an IEC fuse will carry more current for longer than an equivalent rated UL fuse. Randall === This list supported in part by The Vintage Triumph Register === http://www.vtr.org |