mgs
[Top] [All Lists]

Re: battery drain-alternator

To: "Charles & Peggy Robinson" <ccrobins@ktc.com>,
Subject: Re: battery drain-alternator
From: "Paul Hunt" <paul.hunt1@blueyonder.co.uk>
Date: Tue, 20 Apr 2004 09:12:17 +0100
My books indicate 13.8 to 14.2v is what to expect when the alt is at its
maximum output of 34 amps at 6000 rpm (or 3400 rpm in a different section),
at nominal output the regulated voltage is 14.3 to 14.7v.  FWIW the dynamo
control box settings are higher than this, ranging from 14.3 to 15.5v
depending on ambient temperature.

PaulH.

----- Original Message -----
From: "Charles & Peggy Robinson" <ccrobins@ktc.com>
To: "MonteMorris" <mmorris@nemr.net>
Cc: "MG list" <mgs@autox.team.net>
Sent: Monday, April 19, 2004 3:42 PM
Subject: Re: battery drain-alternator


>       I was taught that 13.8 to 14.2 volts -  when the battery is fully
> charged -  was a good rule of thumb.





<Prev in Thread] Current Thread [Next in Thread>