Question: Are the correct length bolts through the fan plate and into the
extension, being used? If not then the fan can spin freely. They must be
able to go through the fan, adapter and extension and be tight with a spring
washer. The only other possible opportunity for it to spin, apart from what
Dick has mentioned would be that the key on the crank is missing. This
sometimes occurs in assembly. However this would mean the timing could never
be measured or set correctly. 