<I've got the condenser lead and terminal lead from the coil
attached to the contact point post on top of the nylon washer as I believe
they should be. >
If I interpret you correctly, you have assembled the wires incorrectly. These
wires should be insulated from the post by the nylon washer. They should only
touch the sprung steel that goes to the contact points themselves. First put
on the lower nylon washer, then the steel strap that goes to the contacts with
the round portion over the lower nylon washer's bushing, then the two wires,
then the upper nylon washer making sure that the bushing portion of the washer
goes into the holes on the terminal ends of the wires thus insulating
everything from the post, then the nut.
Peter Arakelian - '71 TR6, Daily Driver
/// triumphs@autox.team.net mailing list