>From: Steven Trovato <trovato@computer.net>
>"The NEC does not specify ...
>They then go on to give an example of determining the number of outlets on
>one circuit by assigning 1 to 1.5 amperes to each outlet.  Thus a 15 amp
>circuit gets 10 to 15 outlets.

I have always combined the section of code referenced above with another
section which says to only plan on a 80% load for a new circuit.

20 X .8
-------   = 10.67
1.5


Two thirds of a outlet is hard to find, so I always limit my 20A
circuits to 10 outlets.

Rich White  St. Joseph, IL USA