On 28 mar 1997, DANMAS@aol.com wrote:

> As I see it, the following changes will need to be made:
> 
> 1) replace the generator/control box with an alternator

No. Just "flash"[1] the generator, and you'll be fine.
 
> 2) reverse the ammeter leads

Yes.

> 3) swap the ignition coil, or reverse the leads

Somewhat surprisingly, yes.

> 4) swap the battery leads

Obviously!

> 5) reverse the leads to the interior heater

No.

> 6) change the starter

No. The starter motor nor other major electric motors in you car has a 
permanent magnet. So they will run in the same direction regardless of 
polarity.

> b) The windshield wiper motor converts rotary motion to linear motion, so the
> direction of rotation is of no concern.

Again, it will run the same direction.

Your other assumptions re. bi-metal devices etc. are correct.

Various extra equipment may cause problems, esp. radios, electronic 
gadgets of various sorts. 

Egil

[1] I.e. apply the new battery voltage to it for a second.
-- 