>The critical issue, which I believe you correct in a later mailing,
is
>that the fan belt must still line up with the generator
(alternator) and
>crank pulley. I believe these are special to the Tiger, and located
>fairly close to the block already. One could space the generator
back,
>some, but the crank pulley may be as far back as it can get. Need
some
>critical thought/dimensions and availability of pulley sources.
>
>Anyone with experience here?
I agree about moving the fan back by pushing the pulley back. When
I reinstalled my new water pump the fan pulley and generator pulley didn't
line up well. I also installed a larger 4 core radiator. As a result, my
fan is buried deep in the shroud and I'm having heat problems. I recently
bought a NOS Ford 5 bladed asymetrical fan, but haven't had a chance to try
it out. I will take off the water pump and press the pulley fitting as far
back as it will go. I'm hoping this will help.
Rob Kempinski