Warren, yes, I just did because all cars in Holland must have one, 
irrespective of age.
I found a 84 Watt flasher for something like 5 dollars and bought a 
Double Pole Double Throw  switch for 3 dollars. Fitted the flasher can 
close to the original flasher, ran one heavy wire from the fuse box to 
the flasher unit, one heavy wire from the flasher unit through the 
firewall to the DPDT switch in the interior, connected both switch poles 
on the feed side and ran two wires, one from every pole, back through 
the firewall and along the cable harness to the connectors in the 
flasher lines just below the steering box. Replaced the single 
connectors by double connectors, stuck the two wires from the switch 
into the double connectors and Bob was my uncle. It even worked when 
tested! Only thing I don't know yet is what happens when I have my 
trafficator switch to the left or the right (so not neutral) and switch 
on the hazard lights - my steering wheel is not fitted yet.
Hope this story helps. If not, I'm fully prepared to come over and fix 
it for you when you pay my flight!
Good luck.
Jack Aeckerlin, The Netherlands
1964 BJ8 29432

Warren Dietz wrote:

>    Has anyone installed a 4 way flasher(hazard warning switch) in 
> their Healey?
>
> I have been considering this for some time. I see that VB has a switch 
> assembly in their catalog.
>