healeys
[Top] [All Lists]

Re: fuel gauge sending unit - BN2

To: "Brashear, Jack, N" <JNBrashear@garverengineers.com>,
Subject: Re: fuel gauge sending unit - BN2
From: "John Snyder" <helyjohn@cablespeed.com>
Date: Mon, 10 Apr 2006 09:08:04 -0700
I have had success w/ having the old sending unit rebuilt by Mo-Ma in 
Albuquerque  MOMANM@aol.com .  Also, at a Tech Session a few years ago, a 
vendor who is a local M+++ supplier said not to waste time ordering 
replacement sending units because the quality is terrible.

John Snyder


> Hi All, my neighbor has had two faulty new sending units in a row from
> M+++ through a local supplier.  His BN2 has the proper gauge and it
> checks out to be good using the information and procedures that have
> been posted on this list in the past.  His wiring is new and checks out
> to be properly installed.  He added an extra ground wire from the unit
> to the chassis.  The problem apparently lies with the Asian sending unit
> itself.  That is, the gauge shows 1/4 full when the tank is known to be
> 3/4 full, for example.  Other gauges known to work well in other Healeys
> have been substituted with the same results as his gauge.  Does anyone
> know of a source for "Good" sending units??  It seems returning it to
> his supplier means only that another crummy unit will be sent as a
> replacement.  Help from this awesome list would be greatly appreciated.
> Jack




<Prev in Thread] Current Thread [Next in Thread>