healeys
[Top] [All Lists]

Re: BJ8 Generator

To: "Ned Smith" <smithn00@kitepilot.net>
Subject: Re: BJ8 Generator
From: David Nock <healeydoc@sbcglobal.net>
Date: Tue, 7 Mar 2006 08:24:52 -0800
Ned,
        You can turn the generator into a motor and confirm that it will 
charge when installed.
To do this you will need to polarize the generator, To do this use a 
jumper battery and connect the negative side to the case of the 
generator then touch the positive cable to the SMALL terminal on the 
generator. This will make the generator a positive ground generator. 
Now connect the positive cable to the small terminal and then the large 
terminal at the same time. DO NOT touch the large terminal first by its 
self you will damage the generator. When both the terminals are 
connected the generator pulley will turn, this has turned the generator 
into a electric motor. If it does not turn it will not charge.




David Nock
British Car Specialists
Stockton Ca 95205
209-948-8767

www.britishcarspecialists.com
.
.
On Mar 7, 2006, at 6:13 AM, Ned Smith wrote:

> My BJ8 has been converted to Neg. ground and an alternator.  But the
> generator came with the car. Is there a way to tell if it is in working
> order without mounting it on the engine?
>
>
>
> Thanks,
>
>
>
> Ned Smith
>
> BJ8
>
> near Chattanooga, TN




<Prev in Thread] Current Thread [Next in Thread>